Heating blocksHeating block NANOCOLOR VARIO C2, single block

RM0.00

  • The NANOCOLOR VARIO C2 enables a fast and safe performance of all kinds of sample digestions required in water and waste water analysis for up to 12 samples in parallel.
  • Standard parameters for routine digestions such as COD, TOC, total nitrogen, total phosphorus and metals are pre-programmed in the heating blocks and help the user to avoid mistakes.

Package unit 1 Piece(s)

  • Description
  • Additional information

Description

  • Technical Data
  • Learn more
  • Downloads
Brand NANOCOLOR
Type Heating block for chemical-analytical digestions
Bores 12 with 16 mm outer diameter
Display Colored, backlit LCD touch screen
Operation Icon-based menu guidance via touch screen
Temperatures 6 preprogrammed temperatures 70 °C / 100 °C / 120 °C / 148 °C / 150 °C / 160 °C, 6 free memory locations for individual temperature settings
Temperature range 40–160 °C (1 °C increments)
Warm up time From 20 °C to 160 °C within 10 minutes
Heating times 5 preprogrammed heating times, 10 min / 30 min / 60 min / 120 min / cont., 7 free memory locations for individual heating times
Time range 0 h 01 min–9 h 59 min (increments 0 h 01 min)
Temperature stability ±1 °C (according to DIN, EN, ISO and EPA methods)
Safety Replaceable safety covers as contact protection, lockable protective lids, overheating protection
Interfaces Bidirectional serial RS232, USB A (function) and USB B (Host)
Internal quality control With NANOCOLOR T-Set (REF 919917) and NANOCOLOR USB T-Set (REF 919921), optional fully automatic calibration and generation of a test certificate for instrument control and monitoring
Language DE / EN / FR / ES / HU / PL / CZ / TR / DK
Update Free via internet / PC and USB stick
Operating range 10–40 °C, max. 80 % relative humidity (non-condensing)
Power supply 110–230 V AC, 50 / 60 Hz
Power consumption 150 / 300 W
Dimensions 169 x 282 x 146 mm
Weight 2 kg
Warranty 2 Years
CE certified Yes
Scope of delivery Heating block, power cable, protective covering, manual, data cable, software DVD and certificate
Hazardous material No

NANOCOLOR VARIO 4, VARIO C 2 and VARIO C2 M – Heating blocks for reliable digestions

The NANOCOLOR heating blocks enable a fast and safe performance of all kinds of sample digestions required in water and waste water analysis. Standard parameters for routine digestions such as COD, TOC, total nitrogen, total phosphorus and metals are pre-programmed in the heating blocks and help the user to avoid mistakes.

Easy

  • User-friendly touch screen
  • Intuitive usage via icons
  • Operation without the need for intensive training

Fast

  • All important parameters within 30 minutes
  • Extremely short heating-up times
  • Call up of heating programs in a matter of seconds

Secure

  • High temperature stability
  • Graphically visualized heating curves
  • Internal quality control via NANOCOLOR T‑Set

The small one and the big one

The heating block NANOCOLOR VARIO C2 enables the simultaneous digestion of up to 12 samples. For a higher sample throughput the NANOCOLOR VARIO 4 is perfectly suited, as it allows up to 24 simultaneous digestions in two separately controllable heating units. Therefore, MACHEREY‑NAGEL offers the appropriate heating block to each user for routine analysis in the laboratory. The NANOCOLOR heating blocks are equipped with lockable protective lids and a touch protection for increased work safety. The NANOCOLOR VARIO C2 M heating block with two 22 mm and eight 16 mm holes is available for the digestion of large sample volumes as part of metal analysis.

Extremely versatile and maximally secure

In addition to the preprogrammed temperatures and heating times, a large number of user-specific digestion methods can be stored. The USB and RS232 interfaces allow an easy connection to a PC and enable the convenient linkage to the NANOCONTROL inspection equipment monitoring tools. The graphical representation of the heating curves enhances transparency about the temperature stability. The electronic overtemperature sensor protects the heating block from overheating.

Temperature testing and calibration

A temperature test can be performed using the NANOCOLOR T‑Sets to safeguard results against authorities and supervisors. The free PC software of the heating blocks facilitates checking of temperatures and the creation of the respective reports. After measurement data transfer via the interfaces using the PC software, the testing certificate is created directly, which ensures a GLP-compliant documentation of all equipment testing.

heating block

Additional information

pH range

0.0–6.0, 0.3–2.3, 0–14 PT, 0–14, 1.7–3.8, 2.0–9.0, 3.1–8.3, 3.6–6.1 PT, 3.6–6.1, 4.0–7.0, 4.5–10.0 PT, 4.5–10.0, 5.1–7.2, 6.0–10.0, 6.0–7.7, 7.0–14.0, 7.5–9.5, 7.9–9.8