SpectrophotometersSpectrophotometer NANOCOLOR UV/VIS II, 190−1100 nm
RM0.00
The spectrophotometer NANOCOLOR UV/VIS II is a high-precision instrument applicable in all areas of water and wastewater analysis. MACHEREY‑NAGEL revolutionizes the daily laboratory work with this new spectrophotometer by the combination of premium high-tech components with outstanding usability.
Package unit 1 Piece(s)
- Description
- Additional information
Description
- Technical Data
- Learn more
- Downloads
Brand | NANOCOLOR |
Type | Spectrophotometer with reference detector technology (RDT) |
Light source | Halogen lamp (visible range), Deuterium lamp (UV range) |
Optical system | Monochromator |
Wavelength | 190–1100 nm |
Wavelength accuracy | ± 1 nm |
Wavelength resolution | 0.1 nm |
Wavelength reproducibility | <0.5 nm |
Wavelength calibration | Automatic |
Wavelength selection | Automatic, barcode, manual |
Scan speed | 1 complete scan in less than 1 min |
Spectral bandwidth | < 2 nm |
Photometric range | ± 3.0 A in wavelength range 200–900 nm |
Photometric accuracy | 0.005 A at 0.0–0.5 A; 1 % at 0.5–2.0 A |
Photometric linearity | < 0.5 % at ≤ 2 A; ≤ 1 % at > 2 A |
Stray light | < 0.05 % |
Measuring modes | More than 200 preprogrammed tests and special methods, 100 optionally programmable methods, absorbance, transmission, factor, kinetics, 2-point calibration, scan, nephelometric turbidity measurement |
Preprogrammed tests | NANOCOLOR tube tests and standard tests |
Turbidity measurement | Nephelometric turbidity measurement at 860 nm (based on ISO 7027), 0.1–1000 NTU |
Cuvette slot | Round tubes 16 mm OD, rectangular cuvettes 10 mm, 20 mm, 40 mm, 50 mm |
External light | Insensitive to external light, fast measurements without cuvette slot cover |
Data memory | 16 GB Micro SDHC card, 5000 measured data sets, 100 spectra and color measurements, GLP-conform |
Display | 10.1″ LED backlit HD display, anti-reflective cover glass with projected capacitive touch screen (PCAP) |
Internal quality control | With NANOCONTROL NANOCHECK 2.0 |
Operation | Barcode technology, icon-based menu guidance, touch screen |
Language | DE / EN / FR / ES / PT / PL / HU / NL / CZ / RO / IT |
Interfaces | LAN, 2 x USB (host), 1 x USB (function) and RS232 |
Update | Free via USB stick |
Operating range | 10–40 °C, max. 80 % relative humidity (non-condensing) |
Power supply | 110–240 V AC, 50 / 60 Hz |
Dimensions | 400 x 440 x 170 mm |
Weight | 6.5 kg |
Warranty | 2 Years |
CE certified | Yes |
Scope of delivery | Photometer, manual (quick start guide), touch pen, protective covering, power cable, USB cable, USB stick, calibration cuvette, certificate and cleaning cloth |
Hazardous material | No |
NANOCOLOR VIS II and UV/VIS II – Spectrophotometers for high-precision analysis
The NANOCOLOR VIS II and NANOCOLOR UV/VIS II are high-precision measurement instruments applicable in all areas of water and wastewater analysis. MACHEREY‑NAGEL revolutionizes the daily laboratory work with these two new spectrophotometers, combining premium high-tech instruments with outstanding usability. With their intuitive, icon-based menu guidance, these innovative photometers can be used like a smartphone or tablet. The clearly arranged, high-resolution touch screen display makes your daily measurement routine a real pleasure.
Powerful technology
The new NANOCOLOR spectrophotometers impress with high-class technology and optics. The spectral bandwidth of the NANOCOLOR UV/VIS II of < 2 nm allows high-precision measurements. The optical set-up and the clever technique of both devices enable measurements without protective cover; a big advantage for smooth lab processes. With a 2D barcode scanner and cuvette recognition, all steps from measuring over displaying to storing of the result are part of a fully automated sequence.
The allrounders for all requirements
As comprehensive spectrophotometers, the NANOCOLOR VIS II and UV/VIS II, meet all requirements of your daily laboratory work. They come with well-known barcode technology for a rapid measurement of NANOCOLOR tube tests. In addition, they offer extensive color measurement possibilities and real-time scan recording. Next the nephelometric turbidity measurement and the turbidity measurement in transmitted light, the preprogrammed MEBAK methods allow a comprehensive brewery analysis. The simple menu navigation and the icon-based pictogram instructions for the performance of cuvette tests, reduce the complexity of the daily laboratory work. The clear result screen enables an easy assignment of additional sample information and measurement results. The systematic menu guidance for the calibration of special methods allows even inexperienced users to program methods for user specific applications.
Smart
- Outstanding usability due to touch screen
- 10.1“ HD display for a clear overview
- Unique user experience due to icon based menu guidance
Precise
- High quality optics with reference detector technology
- Safe results due to automatic turbidity control function (NTU-check)
- Safeguarding of results via integrated IQC menu
Impressively versatile
- Future-proof interfaces
- Color measurements, turbidity measurements and scans
- Applicable in all fields of water and waste water analysis
The next audit will be a breeze
Quality is of high importance for MACHEREY‑NAGEL. Therefore, our new spectrophotometers are equipped with extensive quality control features. Besides the integrated, f. o.c. inspection equipment monitoring tools, the devices offer a variety of quality control functions for e. g. standard measurements, multiple determinations and dilution series. IQC cards are generated directly in the device and can be printed or exported
for documentation purposes. Therefore, NANOCOLOR VIS II and UV/VIS II offer easy to use control options, allowing an efficient and accurate internal quality control perfectly integrated in your daily work.
Striking interface options for smart connectivity
The connection of measuring devices to laboratory information systems (LIMS) plays a more and more important role in many industries. Therefore, the NANOCOLOR VIS II and NANOCOLOR UV/VIS II are equipped with all important interfaces (LAN, RS232, USB) for the connection to laboratory information systems. In addition, the integrated LIMS configurator allows a customized adaptation for many kinds of data for transfer. An easily accessible USB port increases the comfort of data exchange with mass storage media or the usage of a barcode reader, scanner or printer.
Additional information
pH range | 0.0–6.0, 0.3–2.3, 0–14 PT, 0–14, 1.7–3.8, 2.0–9.0, 3.1–8.3, 3.6–6.1 PT, 3.6–6.1, 4.0–7.0, 4.5–10.0 PT, 4.5–10.0, 5.1–7.2, 6.0–10.0, 6.0–7.7, 7.0–14.0, 7.5–9.5, 7.9–9.8 |
---|