ProbeORP digital sensor EHAN for ODEON with cartridge
RM0.00
• Combination sensor: ORP & temperature
• Range of measure ORP: -1000 to + 1000mV
• T°C: 0.00 to + 50.00°C
• Interchangeable cartridge with plastogel
• Digital communication RS-485 Modbus
APPLICATION:
• Urban waste treatment (inlet, aeration bassin, outlet)
• Treatment of Industrial effluent (optimization process of nitrifying/denitrifying)
• Deodorization channels
- Description
- Additional information
Description
- Technical Data
- Downloads
PHYSICAL ANCHEMICAL TECHNOLOGY:
The electrolyte “PLASTOGEL®” of DIGISENS Ponsel sensor communicates directly with the external environment without interposition of capillary or porous. There is therefore no risk of clogging or reference defusing.
Temperature: Measures via CTN
DIGITAL COMMUNICATION / INTEGRATED TRANSMITTER:
The PONSEL sensor connects to any type of recorder, transmitter, remote management system or PLC with a Modbus RS485 input. Thanks to indexing the sensor, over 200 sensors can be connected to a recorder.
Resistant to interferences: preamplification into the sensor and digital signal processing. All data regarding the calibration, the historic and users are saved directly in the digital EHAN sensor.
MECHANICS:
A handle in Delrin material ensures the mechanical strength of the sensor and the sealing of the cable. Compact, robust and lightweight, the sensor can be used in portative or online version.
Technical data
ORP Measure | |
Principle of ORP measure | Combination Electrode (ORP/reference) platinium ring, Reference Ag/AgCI. Gelled electrolyte (KCI) |
Range of measures | – 1000,0 to + 1000,0 mV |
Resolution | +/- 0.1 mV |
Precision | +/- 10 mV |
Answer time | 90 s |
Temperature measurement | |
Principle of measure T°C | CTN |
Temperature | 0,00 °C to + 50,00°C |
Resolution | 0,01 °C, Precision : + 0,5°C |
Temperature of storage | 0°C to + 60°C |
Protection scale | IP 68 |
Interface signal | Modbus RS-485 standard and SDI-12 |
Refresh rate measurement | Maximum < 1 second |
Sensor power | 5 to 12 volts |
Consumption | Standby : 25 μA Average RS485 (1 measure/second) : 20 mA Pulse current : 500 mA Heating time : 100 mS |
Sensor | |
Dimensions of sensor mounted | Mounted sensor length: gland (262 mm) not included ; Length with gland : 324 mm |
Weight | 350 g (sensor + cable) |
Material in contact with the environment | PVC, POM-C,platinium, Polyurethane |
Maximum Pression | 5 bars |
Cable/ connection | 9 armored connectors, polyurethane jacket, bare wires or waterproof metal Fischer connector |